{"product_id":"duravent-duraliner-6-15-degree-stainless-steel-elbow-adapter","title":"DuraVent DuraLiner 6\" 15 Degree Stainless Steel Elbow Adapter","description":"\u003cp\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/yeoX0imW9kI\" height=\"315\" width=\"100%\" allow=\"fullscreen;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003eDuraLiner ensures safe and efficient venting of heating appliances while protecting the masonry chimney from the damaging effects of flue gas. It is the only factory-insulated product with zero\/zero clearance for high-heat wood-burning appliances. No need to uncoil flex, insulate a majority of the pipe, or protect the insulation when installing. A smooth inner means less creosote buildup.\u003c\/p\u003e\n\u003cp\u003eInstallers reduce labor time by 50% or more with DuraLiner. No time was wasted wrapping insulation around the liner for UL 1777 approval.\u003c\/p\u003e\n\u003cp\u003eNo spacers are needed to maintain clearance in tight offsets or dampers. Approved for use in both the USA and Canada.\u003c\/p\u003e\n\u003ch1\u003eWhat's Included\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e15° Elbow Adapter (SS)\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eFeatures\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003eUse to offset obstructions as needed. Use as a stove connector to DuraLiner.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eBuilt-in fittings for connection to DuraLiner.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eElbows are single-wall.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eSpecifications\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eDuraVent\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6DLR-E15ADSS\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e6\" DuraLiner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eElbow Adapter\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eWarranty\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 46.5779%;\" data-mce-style=\"width: 46.5779%;\"\u003e\n\u003cdiv style=\"text-align: start;\" data-mce-style=\"text-align: start;\"\u003e\u003cimg style=\"float: none;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0100\/7917\/4734\/files\/Lifetime_Warranty_Badge_240x240.jpg?v=1682130235\" data-mce-style=\"float: none;\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0100\/7917\/4734\/files\/Lifetime_Warranty_Badge_240x240.jpg?v=1682130235\"\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 50.3802%;\" data-mce-style=\"width: 50.3802%;\"\u003eDuraVent, Inc. (“DuraVent”) provides this limited lifetime warranty for all of its products with the exception of Ventinox® (lifetime), and PolyPro® (ten years). Subject to the limitations set forth below, DuraVent warrants that its products will be free from defects in material or manufacturing, if properly installed, maintained, and used.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cdetails\u003e \u003csummary\u003eClick to See \u003cstrong\u003eWarranty Coverage and Limitations\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eDuraVent, Inc. (“DuraVent”) provides this limited lifetime warranty for all of its products with the exception of Ventinox® (lifetime), and PolyPro® (ten years). Subject to the limitations set forth below, DuraVent warrants that its products will be free from defects in material or manufacturing, if properly installed, maintained and used. DuraVent products are fully warranted if installed only by a professional installer. This Warranty is transferable from the original homeowner to the buyer of the home. This warranty does not cover normal wear and tear, smoke damage or damage caused by chimney fires, acts of God, or any product that was: (1) purchased other than from an authorized DuraVent dealer, retailer or distributor; (2) modified or altered; (3) improperly serviced, inspected or cleaned; or (4) subject to negligence or any use not in accordance with the installation instructions included with the product as determined by DuraVent.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDuraVent provides the following warranties for its products: One Hundred Percent (100%) MSRP 15 years from the date of purchase, and Fifty Percent (50%) thereafter, except for the following limitations on: all Termination Caps and DuraBlack® are warranted at One Hundred Percent (100%) for five years. All warranty obligations of DuraVent shall be limited to repair or replacement of the defective product pursuant to the terms and conditions applicable to each product line. These remedies shall constitute DuraVent’s sole obligation and sole remedy under this warranty. This warranty provides no cash surrender value. The terms and conditions of this warranty may not be modified, altered or waived by any action, inaction or representation, whether oral or in writing, except upon the express, written authority of an executive officer of DuraVent.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eCorn, bio-fuels, driftwood or other wood containing salt, preservative-treated lumber, plastic and household trash or garbage, or wood pellets containing such materials must not be burned in the appliance or fireplace. In case of a chimney fire, the chimney must be inspected and approved by a certified Chimney Sweep before reuse. After each annual inspection, maintenance, and cleaning, the certified Chimney Sweep must fill out and date the appropriate section of the warranty card provided with the chimney liner.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eLIMITATIONS ON INTERNET SALES: Notwithstanding any other terms or conditions of this Limited Lifetime Warranty, DuraVent provides no warranty for the following specific products if such products are not installed by a qualified professional installer: DuraTech®, DuraTech® DTC, DuraTech® Premium, DuraPlus HTC®, DDW®, DuraChimney® II, PelletVent Pro®, DirectVent Pro®, FasNSeal®, FasNSeal® W2, FasNSeal® Flex, and PolyPro®, and DuraVent’s relining products including DuraLiner®, DuraFlex® (SW, Pro, 316, 304), and Ventinox®. For purposes of this warranty, a trained professional installer is defined as one of the following: licensed contractors with prior chimney installation experience, CSIA Certified Chimney Sweeps, NFI Certified Specialists, or WETT Certified Professionals.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDuraVent must be notified and given the opportunity to inspect defective product prior to replacement under the terms of this limited lifetime warranty. All warranty claims must be submitted with proof of purchase. Labor and installation costs are not covered under this warranty. To obtain warranty service contact: DuraVent Warranty Service, 877 Cotting Ct., Vacaville CA 95688, or call 800-835-4429.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eWHERE LAWFUL, DURAVENT DISCLAIMS ALL OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT WILL DURAVENT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE OR SPECIAL DAMAGES OR DIRECT OR INDIRECT LOSS OF ANY KIND, INCLUDING BUT NOT LIMITED TO PROPERTY DAMAGE AND PERSONAL INJURY. DURAVENT’S ENTIRE LIABILITY IS LIMITED TO THE PURCHASE PRICE OF THIS PRODUCT. SOME STATES DO NOT ALLOW LIMITATIONS ON IMPLIED WARRANTIES, OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU. THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0813\/8725\/8148\/files\/L209_810007492_DV-Limited-Lifetime-Warranty_06-2021.pdf?v=1695119839\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0813\/8725\/8148\/files\/L209_810007492_DV-Limited-Lifetime-Warranty_06-2021.pdf?v=1695119839\"\u003eDownload DuraVent Limited Lifetime Warranty here.\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/details\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003eDocuments \u0026amp; Files\u003c\/h1\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0813\/8725\/8148\/files\/L703_810007526_Brochure_DuraLiner_03-24-20_V3_Web.pdf?v=1695779393\" target=\"_blank\"\u003eProduct Brochure\u003c\/a\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0813\/8725\/8148\/files\/DV_DL_CT-001E_04-23.pdf?v=1695779467\" target=\"_blank\"\u003eDuraLiner Catalog\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0813\/8725\/8148\/files\/L402_820003162_Install-Instructions_DuraLiner.pdf?v=1695779526\" target=\"_blank\"\u003eInstallation Instructions\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0813\/8725\/8148\/files\/L4020_820016191.pdf?v=1695779571\" target=\"_blank\"\u003eMasonry Thimble L402 Installation Instruction Addendum\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch1\u003eFrequently Asked Questions\u003c\/h1\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cdetails\u003e \u003csummary\u003e\u003cstrong\u003eWhat are DuraLiner's Specifications?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDuraLiner is a high-temperature, insulated double-wall masonry relining system for use with appliances fueled by gas, pellet, oil, wood, or coal. It safely protects masonry chimneys from the damaging effects of flue product condensation.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMaterials and Construction\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e.016″ 304 stainless steel inner liner. Rigid relining pipe: double-walled with 304 stainless steel inner and galvalume outer. Factory insulated between inner and outer walls. DuraLiner Rigid Pipe in round or oval, is constructed with built-in fittings and pre-drilled holes (stainless steel rivets included). Round 5″ DuraLiner rigid pipe is constructed with built-in twist-lock and pre-drilled holes.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClearances\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRigid double wall: 0″ clearance between the liner and masonry and 0″ clearance between the masonry and combustibles. DuraLiner Flex: 1″ clearance to masonry. Zero clearance with insulation.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDiameters\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e5“, 6″ and 8”\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eListings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUL Listed to UL 1777 (MH14420), ULC Listed to ULC S635 .\u003cbr\u003e\u003c\/p\u003e\n\u003c\/details\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cdetails\u003e \u003csummary\u003e\u003cstrong\u003eWhat is DuraLiner's Typical Installation?\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eRefer to our Typical Installation drawings to select the appropriate component parts for your installation\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe inner pipe diameter should match the outlet size of the appliance.\u003c\/li\u003e\n\u003cli\u003eCheck the appliance manufacturer’s installation instructions for any venting restrictions.\u003c\/li\u003e\n\u003cli\u003eBe fire safe! Follow local building codes and have your venting system inspected.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0813\/8725\/8148\/files\/DVDuraLiner.jpg?v=1695212169\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMore Typical Installations:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0813\/8725\/8148\/files\/DVDuraLiner2.jpg?v=1695212168\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eInstallation Key\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eExtend-A-Cap Kit\u003c\/li\u003e\n\u003cli\u003eRound Tee with Round Branch\u003c\/li\u003e\n\u003cli\u003eDuraTech or DuraPlus Chimney\u003c\/li\u003e\n\u003cli\u003eTee with Removeable Snout\u003c\/li\u003e\n\u003cli\u003eDuraLiner – flexible length\u003c\/li\u003e\n\u003cli\u003eMasonry Thimble w\/ Slip Connector\u003c\/li\u003e\n\u003cli\u003eSlip Connector and Hanger\u003c\/li\u003e\n\u003cli\u003e30° or 45° SS Elbow\u003c\/li\u003e\n\u003cli\u003eTransition Anchor Plate\u003c\/li\u003e\n\u003cli\u003eProMesh \u0026amp; ProFoil\u003c\/li\u003e\n\u003cli\u003eInsulation Clamp\u003c\/li\u003e\n\u003cli\u003eDuraLiner Appliance Connector\u003c\/li\u003e\n\u003cli\u003eDVL or DuraBlack Stovepipe\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlanning Your Installation:\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eRefer to the Typical Installations for the needed parts for installation.\u003c\/li\u003e\n\u003cli\u003eThe size of the liner should match the outlet size on the appliance.\u003c\/li\u003e\n\u003cli\u003eDetermine use of round or oval pipe based onthe interior shape of the chimney\u003c\/li\u003e\n\u003cli\u003eDetermine the length of liner needed. Subtract 1 1\/2″ overlap per joint on pipe. When using Extend-A-Cap kit, liner must extend 6″ above top of the masonry surface.\u003c\/li\u003e\n\u003cli\u003eMake sure the top of the masonry chimney has a leveled surface to insure a proper fit for the Extend-A-Cap or Transition Anchor Plate and to provide a secure, leak-proof installation.\u003c\/li\u003e\n\u003cli\u003eIf a free-standing appliance is used, select the vent or stovepipe pieces to connect from the appliance to the liner. Refer to installation instructions.\u003c\/li\u003e\n\u003cli\u003eFor Installations using a Transition Anchor Plate, refer to the DuraTech, DuraPlus, or DuraPlus HTC catalog section or installation instructions for proper parts and installation.\u003c\/li\u003e\n\u003cli\u003eImportant! Check to be sure the installation complies with all local and national code requirements, including clearance to combustibles. Contact the local building inspector for permit requirements.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDesign Recommendations\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe following design recommendations are a general guideline to assist in the design and selection of liner components for your installation. Always follow DuraVent installation instructions enclosed with the cap or support box before installing your chimney system.\u003c\/li\u003e\n\u003cli\u003eBefore relining a chimney, it should be cleaned and inspected, by a certified chimney sweep, to verify the integrity of the mortar and masonry.\u003c\/li\u003e\n\u003cli\u003eDuraLiner is approved for 0″ clearance between the liner and masonry and 0″ clearance between the masonry and combustibles.\u003c\/li\u003e\n\u003cli\u003eDuraLiner is used for wood-burning appliances when zeroclearance or oval pipe is needed.\u003c\/li\u003e\n\u003cli\u003eRefer to the appliance manufacturer for installation requirements affecting venting. Keep the vent path as straight as possible for best performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRestore Deteriorating Chimneys with DuraLiner\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eWhen a masonry chimney is damaged or has fallen down, it can be replaced with a safe, listed liner system or factory-built chimney. DuraLiner, when used with a Transition Anchor Plate and in combination with DuraTech, DuraPlus, or DuraPlus HTC Chimneys, replaces the damaged masonry chimney with a safe, efficient, and economical listed chimney system (DuraPlus HTC is listed for use in Canada). See Typical Installations for details.\u003cbr\u003e\u003c\/p\u003e\n\u003c\/details\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 16.3333px;\"\u003e\n\u003ctd style=\"height: 16.3333px;\"\u003e\u003cdetails\u003e \u003csummary\u003e\u003cstrong\u003eDuraVent DuraLiner Common Questions\u003cbr\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. Is the insulation sleeve required?\u003c\/strong\u003e\u003cbr\u003eYes, if flex sections of DuraLiner. is used above the first flue tile you need a 1 inch clearance or insulation blanket in that upper narrow area above damper.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e2. What are the outside dimensions of the pipe?\u003c\/strong\u003e\u003cbr\u003e8” round is 8 5\/8”, 6” is 6 5\/8”, 6” oval is 4 3\/4” x 7 3\/4”, 8” oval is 4 3\/4” x 10 3\/4”.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e3. How tall can I Extend-A-Cap Termination kit above masonry?\u003c\/strong\u003e\u003cbr\u003eExtend-a-cap kit termination may extend from 5” to 5’ above the top of the masonry chimney. (Note: The standard termination is now obsolete).\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e4. Is DuraLiner® a zero clearance liner?\u003c\/strong\u003e\u003cbr\u003eYes. Double-wall DuraLiner. has a 0” clearance to combustibles inside masonry and zero clearance from exterior of masonry to building framing.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e5. Is it okay to burn coal or oil?\u003c\/strong\u003e\u003cbr\u003eYes. It is an all-fuel liner ap-proved for wood gas and coal.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e6. Is the Transition Anchor Plate approved for both DuraTech® and DuraPlus® insulated chimney extension?\u003c\/strong\u003e\u003cbr\u003eYes either chimney may be used.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e7. What connects the DuraLiner® to the chimney above Transition Plate?\u003c\/strong\u003e\u003cbr\u003eYou must use the Slip Connector Hanger assembly to join inners.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e8. Is it UL 1777 tested?\u003c\/strong\u003e\u003cbr\u003eYes.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e9. Can I use the insulation sleeve for other brands of pipe?\u003c\/strong\u003e\u003cbr\u003eNo, it is only listed for use with DuraVent®.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e10. Is the 8” oval equal to the 8” round?\u003c\/strong\u003e\u003cbr\u003eYes, they are essentially the same.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e11. How do I connect DuraLiner® Pipe?\u003c\/strong\u003e\u003cbr\u003eUse a pop-rivet gun and the rivets provided with each length of pipe.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e12. How do I install a Wall-Pass-Through?\u003c\/strong\u003e\u003cbr\u003eFollow the installations instructions. For use through combustible wall.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e13. Why is the oval tee single wall?\u003c\/strong\u003e\u003cbr\u003eTo keep width to a minimum.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e14. How can I order a masonry thimble with a slip connector?\u003c\/strong\u003e\u003cbr\u003eIt is available in our catalog. (stock #s: 5DLR-MTSC1: 810014030, 6DLR-MTSC1: 810014031, 8DLR-MTSC1: 810014032.)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e15. What type of stainless is used?\u003c\/strong\u003e\u003cbr\u003e304 type stainless steel.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e16. What is the clearance to combustibles?\u003c\/strong\u003e\u003cbr\u003eThere is no clearance to combustibles when used in masonry.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e17. What is more flexible, oval or round?\u003c\/strong\u003e\u003cbr\u003eOval.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e18. Can I use my own masonry termination caps?\u003c\/strong\u003e\u003cbr\u003eNo. You must use a DuraVent. cap for termination.\u003c\/p\u003e\n\u003c\/details\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable data-mce-fragment=\"1\" width=\"100%\"\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\" style=\"height: 16.3333px;\" data-mce-style=\"height: 16.3333px;\"\u003e\n\u003ctd data-mce-fragment=\"1\" style=\"height: 16.3333px;\" data-mce-style=\"height: 16.3333px;\"\u003e\u003cdetails data-mce-fragment=\"1\"\u003e \u003csummary data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWhat are the DuraVent product lines?\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/strong\u003e\u003c\/summary\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eDuraVent offers the following product lines:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eDuraTech 5″-8″: All-fuel, double-wall chimney system. UL 103 HT and ULC S604.\u003cbr\u003e\u003cbr\u003eDuraTech 10″-24″: All-fuel, double-wall chimney system. UL 103.\u003cbr\u003e\u003cbr\u003eDuraTech Canada is a double-wall, all-fuel chimney system for use with wood stoves, wood fireplaces, and other appliances using wood, oil, gas, or coal.\u003cbr\u003e\u003cbr\u003eDuraPlus: Triple-wall all-fuel chimney with two layers of insulation.\u003cbr\u003e\u003cbr\u003eDuraPlus HTC: Double-wall all-fuel chimney built to Canadian standards.\u003cbr\u003e\u003cbr\u003eDuraChimney II: Double-wall air-cooled chimney for pre-fabricated masonry chimneys.\u003cbr\u003e\u003cbr\u003eCombustion Air Systems: DuraVent’s exclusive, patent-pending system is designed to bring in outside combustion air directly to your wood or pellet stoves.\u003cbr\u003e\u003cbr\u003eDuraBlack: Single-wall stovepipe.\u003cbr\u003e\u003cbr\u003eDVL: Double-wall stovepipe.\u003cbr\u003e\u003cbr\u003eDuraLiner: Double-wall factory insulated masonry relining system.\u003cbr\u003e\u003cbr\u003eDuraFlex: Flexible stainless steel liners.\u003cbr\u003e\u003cbr\u003eDuraFlex Aluminum: Flexible aluminum relining for masonry chimney. UL 1777 and ULC S635.\u003cbr\u003e\u003cbr\u003eVentinox: Flexible stainless steel liner.\u003cbr\u003e\u003cbr\u003eCVS: Provides Ortal Branded Fireplace Systems and as a Direct Vent for Pellet Stoves.\u003cbr\u003e\u003cbr\u003ePelletVent: Multi-fuel vent.\u003cbr\u003e\u003cbr\u003ePelletVent Pro: Vents appliances using oil, wood pellets, corn, and other biofuels.\u003cbr\u003e\u003cbr\u003eDirectVent Pro: Unitized, co-axial venting system for direct vent gas or propane stoves, heaters, and fireplaces.\u003cbr\u003e\u003cbr\u003eType B Gas Vent: Vents natural gas, liquid propane category I, and draft-hood equipped appliances\u003cbr\u003e\u003cbr\u003eFasNSeal: Single, double-wall, flex, and concentric venting for category II, III, and IV appliances.\u003cbr\u003e\u003cbr\u003eFasNSeal 80\/90: Combined Category I and IV venting for Gas-Burning Appliances.\u003cbr\u003e\u003cbr\u003ePolyPro: Single-wall, flex, and concentric venting made of polypropylene for category II and IV condensing appliances that operate up to 248 degrees.\u003cbr\u003e\u003cbr\u003ePolyPro Flex: PolyPro double-wall flex lining system. Environmentally safe venting system for high-efficiency appliances, including water heaters, condensing boilers, and warm air furnaces. ULC S636.\u003cbr\u003e\u003cbr\u003eDuraSeal: Single-Wall and Double-Wall Special Gas Vent Boiler Adapters.\u003cbr\u003e\u003cbr\u003eDuraStack: A modular double-wall, positive pressure chimney for use with boiler breeching and stack, engine exhaust, and grease duct (DIS only)\u003cbr\u003e\u003cbr\u003eDuraStack Pro: Models DIS and DAS. Modular Double-Wall Positive Pressure Chimney for Boiler Breeching, Stack, and Engine Exhaust.\u003c\/p\u003e\n\u003c\/details\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"DuraVent","offers":[{"title":"Default Title","offer_id":45110385967274,"sku":"6DLR-E15ADSS","price":87.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0100\/7917\/4734\/files\/DuraVent-DuraLiner-6-15-Degree-Stainless-Steel-Elbow-Adapter.jpg?v=1696133874","url":"https:\/\/usfireplacestore.com\/products\/duravent-duraliner-6-15-degree-stainless-steel-elbow-adapter","provider":"US Fireplace Store","version":"1.0","type":"link"}