Skip to content

Free Shipping Over $300 • Need Help? Text or Call 888-992-1556

Skip to product information
1 of 2

SKU:OB00950

Osburn 950 Wood Stove

Osburn 950 Wood Stove

Regular price $1,849.00
Regular price Sale price $1,849.00
Sale Sold out

Options/Accessories

Add Extended Protection Warranty

-- Please Select --

1 Year

2 Years

3 Years

No, Thank You

Venting Options

  • Free Shipping on Orders Over $300
  • Same-Day Order Processing
  • Easy Monthly Installments Starting at 0% APR*
Got a question?
• Text or call 888-992-1556
• Email support@usfireplacestore.com
• Start a live chat

Our team is available to serve you 8:00 AM - 11:59 PM ET, 7 days a week.

Osburn products are made to order. The estimated lead time is 12-18 weeks.

Description

Equipped with high-density bricks, a top heat deflector to redirect heat in front of the stove as well as side panels that reduce clearances, the Osburn 950 offers quality and performance.. Enjoy your winter evenings more than ever before!

        Appliance Performance 
        Fuel type : Dry cordwood (16" recommended)
        Recommended heating area-ft² : () 250 - 1,200
        Overall firebox volume-ft³ : 1.7
        EPA loading volume-ft³ : 1.55
        Maximum burn time : () 5 h
        Maximum heat output-dry cordwood : (2) 45,000 BTU/h (13.19 kW)
        Overall heat output rate < : (2) (3) 12,124 BTU/h (3.55 kW) to 26,700 BTU/h (7.83 kW)
        Average overall efficiency (dry cordwood) : (3) 74 % (HHV) (4) 79 % (LHV) (5)
        Optimum overall efficiency : (6) (7) 80 %
        Optimum heat transfer efficiency : (8) 79 %
        Average particulate emissions rate : (9) 1.8 g/h
        Average CO : (10) 74 g/h

        (1) Values are as measured per test method, except for the recommended heating area, firebox volume, maximum burn time, and maximum heat output.
        (*) Recommended heating area and maximum burn time may vary subject to location in the home, chimney draft, heat loss factors, climate, fuel type, and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure.
        (2) The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³ and reloading intervals ranging from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish. The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.
        (3) As measured per CSA B415.1-10 stack loss method.
        (4) Higher Heating Value of the fuel.
        (5) Lower Heating Value of the fuel.
        (6) Performances based on a fuel load prescribed by the standard at 7 lb/ft³ and with a moisture content between 19% and 25%.
        (7) Optimum overall efficiency at a specific burn rate (LHV).
        (8) The optimum heat transfer efficiency is for the low burn rate (using HHV) and represents the appliance’s ability to convert the energy contained in the wood logs into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
        (9) This appliance is officially tested and certified by an independent agency.
        (10) Carbon monoxide.

         

        General Features
        Combustion technology Non-catalytic
        High-efficiency certified appliance Yes, EPA 2020 approved
        Maximum log length 17"
        Log positioning Loading over depth
        Chimney diameter 6"
        Flue outlet diameter 6"
        Type of chimney CAN/ULC S629, UL 103 HT (2100 °F)
        Minimum chimney height (feet) 12'
        Baffle type C-Cast or equivalent
        Approved for an alcove installation Yes
        Approved for a mobile home installation Yes, with fresh air intake
        Shipping Weight 317 lb (144 kg)
        Door type Single, glass with cast iron frame
        Glass type Ceramic glass
        Glass surface – dimensions (Width X Height) 10 1/4" x 8 7/8"
        Glass air-wash system Yes
        Overall dimension (Height) 28 7/8''
        Overall dimension (Width) 20 1/4''
        Overall dimension (Depth) 27 7/8''
        Door opening – dimension (Height) 7 5/8"
        Door opening - dimension (Width) 12"
        Firebox – dimension (Height) 11 3/4"
        Firebox – dimension (Width) 14 1/4"
        Firebox – dimension (Depth) 19 1/8"
        Firebox lined with refractory bricks for better heat distribution Yes
        Stainless-steel secondary-air system improving gas combustion Yes
        Steel thickness – body 3/16"
        Steel thickness – top 5/16"
        USA standard (emissions) EPA
        Canadian Standard (emissions) CSA B415.1-10
        USA standard (safety) UL 1482, UL 737
        Canadian standard (safety) ULC S627
        Tested and listed as per applicable standards By an accredited laboratory (CAN/USA)
        Warranty Limited lifetime
         

         

        Options

        Click to see options

        5"Ø Fresh Air Intake Kit for Wood Stove on Legs

        The kit contains one assembled fresh air intake box, two clamps, one white exterior wall termination, black metallic paint, one black pre-glued gasket, one flat rod, one ground rod, and screws. The number of screws may vary depending on the assembly.

        5" X 4' Insulated Flex Pipe for Fresh Air Intake Kit

        • Fits on a fresh air kit adaptor.
        • Consists of a 4 ft. length of 5 in. diameter flexible insulated pipe


        5'' Fresh Air Intake Register with Airtight Damper

        • Allows outside combustion air to feed the appliance
        • Airtight damper prevents air drafts when not in use
        • Fully adjustable wall control included
        • Five-inch diameter for maximum airflow
        • Designed for use with the Osburn wood stoves and inserts

        Blower with Thermodisc

        Osburn Blower with Thermodisc.

        Rigid Firescreen

        Removable screen preventing flying sparks. Enhances the crackle and the incomparable atmosphere of a good fire.


        Accessories

        Click to see accessories

        Adhesive, Gasket and Insulation

        High-Temperature Red Silicone (300 ml - 10.1 fl.oz.)

        High-Temperature Clear Silicone (300 ml - 10.1 fl.oz.)

        Paint

        METALLIC BLACK STOVE PAINT - 342 G (12OZ) AEROSOL

        • High-quality metallic black aerosol stove paint
        • Adheres well and dries quickly
        • Retains color well over time
        • Convenient spray application

        METALLIC BLACK STOVE PAINT - 85 G (3OZ) AEROSOL

        • Color: Black
        • Fits most products
        • Metallic black finish
        • 85 g (3oz) aerosol can

         Maintenance Products

        Start-Up Kit

        --- comes with some high-quality gloves, glass cleaner, a digital moisture reader, and a double wall stove pipe probe thermometer

        Ash Vacuum Cleaner

        --- designed almost exclusively for ash collection

        6" Round Brush with Polypropylene Bristles (3/8" NPT)

        --- efficiently cleans chimneys and a convenient loop for hanging

        Pull Ring (3/8" NPT)

        --- securely connects to brushes and give you that extra safety while you use your chimney rod

        5' Fibreglass Rod (3/8'' Npt)

        --- perfect rod for cleaning chimneys enabling you to install a number of accessories or extenders

        Kevlar Thread Wood Stove And Fireplace Gloves

        --- gloves are recommended for safe and clean use with any type of wood-burning appliance.

        19" Kevlar Thread Sewn Fireplace Gloves

        --- cover the entire forearm to protect against heat sources

        Dry Cleaning Pad

        --- easily cleans the soot from the glass without water

        Wood Appliance Glass Cleaner (500ml - 16.9fl.oz.)

        --- recommended for cleaning the glass of any type of wood-burning appliance

         Meters

        Digital Moisture Reader

        --- accurately measures moisture content in wood logs. Wood should be below 20% humidity content

        Fire Starters

        Wood Particles and Wax Fire Starter

        Sachet Pouches Fire Starter

        Wood and Paraffin Fire Starter Cubes

        --- safe, odorless, soot less, strong burning; can be stored indefinitely and does not dry out

        Fireplace Tool Sets

        Equiss Freestanding Log Holder

        --- intersecting panel design for easy setup; rubber base provides surface protection; easily stored when not in use

        48" Wood Storage with Finishing Trim

        --- accommodates logs up to 18" in length; can be installed built-in or freestanding and configured vertically or horizontally

        Drawer and Tool Kit for Wood Storage Insert

        --- includes fire poker and shovel and can be used for wood storage.

        Heat Shields

        Certified Modular Heat Shield System Extension

        --- reduces clearances by up to 87.5% which includes mounting support brackets and hardware

        53" X 58 1/2" Certified Modular Heat Shield System

         

        Support/Parts

        Do I need an EPA certified or CSAB415.1-10 certified heater?

        You first have to identify what your needs are. If you are looking for ambiance, a temporary heat source in a cottage or a camp, or a simple backup heat source in case of power failure, you do not necessarily need to invest more money in order to buy an EPA or CSAB415.1-10 certified wood heater. However, if your goal is to heat on a regular basis, the extra dollars will prove to be a good investment. Furthermore, it must be noted that certified heaters release up to 90% fewer particles into the atmosphere, which makes wood a renewable and clean source of heat. As a result, if the style and size of the heater you are looking for are available in a certified version, it is highly recommended that you invest in this advanced combustion technology. You will help the environment and reduce your wood consumption by up to 30%.

        NOTE: If you live in the United States, British Columbia, Ontario, Quebec, Nova Scotia, New Brunswick, or Newfoundland, EPA certified wood heaters are mandatory. Exceptions apply to certain categories of products, such as decorative fireplaces. Certain municipalities may also have by-laws that require the installation of an EPA or CSAB415.1-10 wood heater, even though the province does not have an official regulation on wood heating. It must also be noted that in Canada, the CSAB415.1-10 Standard is equivalent to the EPA Standard. A wood heater that meets this Standard will generally comply with the regulation in place.

        How do I determine the size of the heater I need and where should I install it?

        Before answering this question, it is very important that you clearly identify what your needs are. Some people will buy a heater simply to enhance the ambiance of a room, while others will buy a heater as their main source of heat. There is no good or bad reason for buying a wood-heat system. If you simply want to enhance the ambiance of a room, most small to medium size heaters will suit your needs. Simply chose the style you like best, and put the unit in the room where you spend the most time. The heat and look of a glowing fire will create an atmosphere of warmth and coziness.

        If your primary need is to heat, you must verify the heating capacity of your heater based on the technical data provided by the manufacturer. For instance, if you want to heat an 800-square-foot area on one floor, you need to buy a heater with a minimum capacity of 800 sq. ft.

        If you need to heat more than one floor, keep in mind that heat rises. Therefore, a heater located in your basement will help you heat the main floor as well. However, the contrary is not true; a heater located

        on the main floor (ground floor) will not heat the basement. Keep in mind also that the more divisions there are in the house, the harder it will be to distribute the heat evenly.

        If you need to heat two floors, calculate the surface of the lower floor. Then, add 50% of the surface of the upper floor. For instance, if you install a wood-heating system in the basement and you have 800 sq.ft., you will need a heater with a minimum capacity of 1,200 sq. ft. (800 + 400 = 1,200.

        If you need to heat more than two floors, calculate the surface of the lower floor (where the wood-heating system is located). Then, add 50% of the surface of the middle floor, and 25% of the surface of the upper floor. For instance, if you install a heater in the basement and you have 800 sq.ft., you will need a heater with a minimum capacity of 1,400 sq. ft. (800+400+200= 1,400). Consult the drawing below. It will help you understand the explanations provided in this section.

        REMEMBER: We are talking about "zone" heating, not central heating. The room where the heater is located and the rooms directly above it will always reach higher temperatures than the rooms distant from the unit. If you want an even temperature throughout the house, you need to consider a central heating system, such as a warm air wood furnace. Furthermore, you must keep in mind that the size of the heater you need may vary based on the insulation of your house, its exposure to wind, and the number of windows. It will always be prudent to buy a heater with a capacity that is slightly higher than the minimum capacity that you need. For instance, if you need a minimum capacity of 1,400 sq.ft., it will be more prudent to buy a heater with a capacity of 1,600 sq.ft., if not 1,800 sq. ft. There are three main advantages in buying a larger appliance: the increased heating capacity, the ease of loading more and larger logs (as a result of the greater firebox volume), and the increased combustion time (given the higher loading capacity).

        The drawing above gives an example of the minimum heating capacity required for a wood-heating system installed in a house with three floors of 800 sq. ft. each. We assume that the house is well insulated and that air can circulate between each floor through an open stairway and/or floor traps.

        Do I need floor protection under and around my heater?

        Yes, floor protection is required for any wood appliance unless the unit already sits on a non-combustible surface. You have many choices, such as stone, brick, cement board, or tile. You need to consult your owner's manual in order to know the dimensions of the floor protection specific to your model. In Canada, the floor protection must extend in front of the unit by at least 18 inches and by at least 8 inches on each side. In the USA, the floor protection must extend at least 8 inches on each side of the appliance (measured from the door opening) and at least 16 inches in front of the door opening.

        What type of exhaust system do I need?

        Your exhaust system is comprised of two main elements: a chimney and a connector (commonly called "stove pipe").


        Connectors

        Connectors are simply steel pipes that connect the appliance to the insulated chimney. They are normally needed unless the appliance is already inserted into an enclosure (for instance, in the case of a zero-clearance wood fireplace). Connectors do not pass through combustible materials. The term “black pipe” is also often used in the industry. There are two types of connectors:

        - Single-wall pipes

        - Double-wall pipes

        As their name indicates, single-wall pipes have just one wall. A minimum of 18 inches is required between the pipe and a combustible wall. In general, single-wall pipes provide less insulation than double-wall pipes do and therefore require more clearance. This is the main drawback of single-wall pipes. Their advantage is in their cost; they are nearly three times less expensive than double-wall pipes.

        As their name indicates, double-wall pipes have a second wall, i.e., an interior one made of stainless steel. The cushion of air between the two walls provides thermal insulation allowing the appliance to be 

        installed much closer to walls. This is the main advantage of double-wall pipes. The required distance for each heater model is based on the safety tests conducted with each type of connector. You, therefore, need to properly consult the appliance’s owner’s manual in order to know the prescribed clearances from combustible materials.

        Chimney

        There are two types of chimneys: an insulated (or prefabricated) chimney or a masonry chimney. If you have a masonry chimney, it must meet the local building code. It must be lined with refractory bricks or tiles joint together with refractory cement. The chimney diameter should be the same as the appliance’s flue outlet (6 inches for most models). It is rarely the case with masonry chimneys. Their diameter is often bigger than the appliance’s flue outlet. The way to deal with this is to insert inside the masonry chimney a stainless steel liner that has the same diameter as the appliance’s flue outlet. Unless a liner is installed, serious draft problems can occur.

        An insulated chimney (or prefab chimney) is a stainless steel flue that has been tested to resist temperatures as high as 2100F. It has a double wall filled with insulating wool. The majority of insulated chimneys have 2 inches of insulation, while some have just 1 inch. Others are air-insulated and have 3 walls; they are referred to as “triple-wall air-cooled chimneys.

        When we speak of a 6-inch chimney, we are referring to its interior diameter. If the chimney has 2 inches of insulation, the flue will have an exterior diameter of 10 inches.

        In wood-heat system installations, we must use an insulated chimney for any flue that passes through walls, ceilings, attics, and closets (i.e., all combustible surfaces in general). This chimney must also be installed outside the house.

        Why should I install a blower on my wood heater?
        A blower can be installed at the back of most models. This option enables you to redistribute the heat from the back of your heater to the front of it and into the room. By forcing hot air toward the front of the heater, the blower extends the radiation power of your unit. Most appliances can also have a thermodisc installed. A thermodisc is a heat sensor connected to the back of the appliance and wired up to the blower. It will start the blower automatically when the air temperature in the back heat shield reaches approximately 115 °F. Likewise, it will turn the blower off when the temperature in the back heat shield goes below 100 °F.

        Why is the efficiency as per the EPA's test data smaller than the publicized optimum efficiency?

        EPA refers to the CSAB415.1-10 standard for the calculation of the appliance’s efficiency. The efficiency reported as per EPA’s directives consists of an average between four different burn rates, ranging from the lowest burn rate (air intake completely closed) to the highest burn rate (air intake completely open). The optimum efficiency that we publicize is the efficiency obtained according to the same test data, but for the low burn rate only. This efficiency is more realistic for a majority of users whose heating needs require that the unit be used to maximize burn times.

        Can I vent my heater using an existing masonry chimney?

        It is possible to install a heater using your existing masonry chimney. The chimney must comply with the building code of your country, state or province. It usually needs to be lined with refractory bricks, metal, or clay tiles sealed together with fire cement. The diameter of the chimney must be the same as the appliance's flue outlet. If your masonry chimney does not have the same diameter as the appliance's flue outlet, you need to insert a stainless steel liner having the proper diameter. Otherwise, you may face draft problems. There are two types of liners: rigid and flexible liners. Both types are made of stainless steel. They must be certified for venting solid-fuel-burning appliances. Flexible liner is particularly useful when the masonry chimney has one or more deviations. 

        Can I cook on the top of my woodstove?

        It is definitely possible to cook on top of your stove. This can be very useful in case of power failure. A stove fully loaded with wood will easily reach 500 to 700 °F on top. This is sufficient to cook. The use of a pan or other cookware may scratch the paint. An option is to use a cast iron cooking grid or simply lay a piece of stainless steel on top of the stove. 

        Can I remove the legs or pedestal of my stove and convert it into a fireplace insert?

        Unfortunately, there is a major design difference between a freestanding wood stove and a wood insert. The wood insert (like all other inserts) has an extra steel jacket that covers about 2/3 of its firebox on the sides and all of its back. This serves to accumulate the heat radiated by the firebox. The heat is then pushed in front of the unit and into the room by a blower. Without this feature, the heat radiated by the insert would be lost into the masonry cavity. Hence, a stove inserted into a masonry fireplace would not have the same efficiency. Furthermore, its clearances to combustible materials could vary. If the stove has not been tested for this type of installation, it cannot be inserted into a masonry opening. 

        Why is there smoke when I use my heater?
        Possible causes and solutions

        Your heater is new and thin smoke is coming out of the unit’s surface.

        Solution: This is normal when your heater is new and has never been used. The paint needs to be "cured". You need to heat your appliance two or three of times before the curing process is completed. Simply open a window in the room where the unit is located. The amount of smoke produced by the curing process should be very limited. If the area is well ventilated, there is no health hazard.

        The chimney is under negative pressure.

        Solution#1: The chimney may simply be too cold. Light-up a small quantity of newspaper in the appliance, as close as possible to the flue outlet. Leave the door slightly ajar. This small fire will slowly heat up the chimney until it is hot enough to create a normal draft inside the exhaust system. If needed, slowly increase the number of newspapers. When you realize that smoke is being evacuated normally through the exhaust system, you can build a normal fire. If your chimney runs along the outside wall of your house, it is possible to cover it up in order to protect it from the wind and the cold. A covered chimney will heat up faster.

        Solution #2: Negative pressure may be caused by air-moving devices, such as a range hood, a bathroom fan, or an air exchanger. Check if smoking problems occur when those devices are working. If it is the case, make sure you turn them off when you use your heater. Otherwise, you need to make sure that the air leaving the room is replaced by air from outside the house. For instance, you can open a window slightly (by one or two inches). Ideally, the source of fresh air should be located as close as possible to the heater. A good, permanent solution is the installation of a fresh air intake. It should be located as close as possible to the unit. The appliance will draw its combustion air from this nearby supply. It will prevent the house from falling into negative pressure. Some units are designed to receive an adapter on which the fresh air supply pipe can be directly connected. This way, the appliance will always draw its combustion air from outside the house.

        Solution #3: Negative pressure may be caused by wind, due to the interference from a nearby structure. In order to eliminate such interference, the extremity of your chimney should be at least two feet higher than any structure located within a ten-foot radius.

        Does my heater qualify under the LEED program?

        The Leadership in Energy and Environmental Design (LEED) Green Building Rating System™ encourages and accelerates global adoption of sustainable green building and development practices through the creation and implementation of universally understood and accepted tools and performance criteria. LEED is a third-party certification program and an internationally accepted benchmark for the design, construction, and operation of high-performance green buildings. It provides building owners and operators the tools they need to have an immediate and measurable impact on their buildings’ performance.

        The Canadian Green Building Council (CGBC) certifies LEED projects. The Certification is based on the total point score achieved, following an independent review and an audit of selected Credits. With four possible levels of certification (certified, silver, gold, and platinum), LEED® is flexible enough to accommodate a wide range of green building strategies that best fit the constraints and goals of particular projects. The Canadian rating systems are an adaptation of the US Green Building Council's (USGBC) LEED Green Building Rating System, tailored specifically for Canadian climates, construction practices, and regulations. The rating systems are adapted to the Canadian market through an inclusive process that engages stakeholders and experts representing the various sectors of the Canadian industry.

        Wood or pellet stoves, fireplaces, and inserts can qualify under LEED and obtain up to one point provided that they meet the following criteria.

        Why doesn't my heater produce enough heat?

        Possible causes and solutions:

        1- The moisture content of your wood is too high.

        Solution: Make sure you use good, seasoned wood. The wood you burn plays an important role in the overall performance of your heater. Your wood should have been properly dried for about one year. Furthermore, it is better to use hardwood, such as oak, maple, beech, or ash. For the same volume, hardwood will produce more heat. Storage is also very important. Wood that has been cut for one, two, or even more years, will not necessarily be dry if it has been stored in poor conditions. Under extreme conditions, it may have rotted instead of drying. Smaller pieces of wood will dry faster. The wood should be stored in a place where the grass is not too long, and where the wind will be able to circulate between the logs. A 12-inch gap should be kept between the cords. The wood should be placed in the sunniest area and should be protected from the rain and snow on top, but not on the sides. Use a moisture reader to measure the moisture content of your wood. Ideally, it should be below 25%.

        2- The air control mechanism is not open enough.

        Solution: Adjust the air control mechanism in order to keep the flue temperature within the comfort zone (between 250 °F and 475 °F) on your chimney thermometer. The air control mechanism must always be closed gradually. You need to obtain a good bed of red embers and the logs must be completely lit up before you close the air control completely. This can easily take up to one hour.

        3- The logs that you are using are too big.

        Solution: Use smaller pieces of wood and place them to allow proper air circulation between the logs. The same weight of wood cut in many small pieces will produce more heat than fewer, larger logs. Only add big logs when you have a good bed of red embers. Logs with a diameter exceeding 6 inches should always be split. Avoid stacking logs to the top of the firebox.

        4- The chimney draft is too weak.

        Solution #1: In many cases, a weak draft is simply due to insufficient heat in the exhaust system. Build a small, intense fire, and leave the door ajar (never leave the heater unattended). Before inserting larger logs, use dry kindling to obtain a good bed of red embers. Gradually increase the size of the logs. Close the unit’s door when you reach a flue temperature of approximately 475 °F on the chimney thermometer. Leave the air intake fully open for approximately 15 minutes. Then, gradually close the air intake control. Note that there is no danger in letting the temperature inside the flue reach approximately 700 °F during the start-up. This is even favorable in order to properly start your heater. You must, however, avoid maintaining excessive temperatures (above the comfort zone on your thermometer) during a long period of time. Your chimney thermometer should be positioned on the exhaust pipe, approximately 18 inches above the unit.

        Solution #2: Your heater may not have all the oxygen it needs to allow for a sufficient draft. You first need to ensure that the room where the heater is located is sufficiently large and well ventilated. Open the nearest window by approximately 2 inches. If you notice a significant improvement, it is a sign that the unit needs more oxygen. The room may be too insulated or too small. Without an additional source of oxygen, the draft will remain weak and cause the glass to stay dirty.

        Solution #3: The chimney may be too short. In order to obtain a sufficient draft, your chimney must have a minimum height. Twelve feet (from the heater to the chimney cap outside the house) is a minimum. A height of 15 feet or higher is ideal.

        Solution #4: Your exhaust system may be too restrictive or may lack a sufficient rise. Ideally, your exhaust system should not have more than one 90° elbow. Furthermore, all horizontal sections should be as short as possible and have a minimum slope of ¼" per foot.

        Solution #5: Your exhaust system may be oversized. When your chimney is oversized, the volume of air that needs to be warmed up is larger. It is therefore difficult to reach temperatures that will allow for a sufficient draft. Most advanced combustion systems (those certified to EPA/CSAB415.1-10) have a 6" flue outlet (152 mm). If your exhaust system does not have a 6" diameter, a solution is to insert a stainless liner with a 6" diameter inside the exhaust system.

        If you have verified all the points mentioned above and your heater works fine, but still does not produce enough heat, you may be asking for more than what your appliance can realistically give you.

        Stoves, fireplaces, and inserts are used for "zone heating”. It is normal that the heat is distributed unevenly inside your home. It will always be colder in the rooms that are distant from the heater. Furthermore, since heat rises, a heater located at the ground-floor level will not heat your basement.

        Solution 6: It is possible to increase heat circulation between the floors by installing floor traps. The location of your heater is also important. Try to install it in a central location. If you want to heat both your basement and the ground floor, install your heater in the basement. The heat will rise to the upper floors. Verify that the area you try to heat respects your appliance’s heating capacity. Your appliance’s heating capacity can be found in the printed literature, in the owner’s manual, or in the technical data section on our website. Keep in mind that your appliance's heating capacity assumes optimum conditions. It may be too low in situations where a house is poorly insulated, or highly exposed to wind. If you already have an appliance with a high heating capacity that works normally but does not heat enough, you probably need a central heating system, such as a warm air wood furnace.

        Why does the fire go out when I close the loading door?

        Possible causes and solutions:

        1- The moisture content of your wood is too high.

        Solution: Make sure you use good, seasoned cordwood. The wood you burn plays an important role in the overall performance of your heater. Your wood should have been properly dried for approximately one year. Storage is also key. Wood that has been cut for one, two, or even more years will not necessarily be dry if it has been stored in poor conditions. Under extreme conditions, it may have rotten instead of drying. Smaller pieces of wood will dry faster. The wood should be stored in a place where the grass is not too long, and where the wind will be able to circulate between the logs. A 12-inch gap should be kept between the cords. The wood should be placed in the sunniest area and should be protected from the rain and snow on top, but not on the sides. Use a moisture reader to measure the moisture content of your wood. Ideally, it should be below 25%.

        2- The air control mechanism is not open enough.

        Solution: Adjust the air control mechanism in order to keep the flue temperature within the comfort zone (between 250 °F and 475 °F) on your chimney thermometer. The air control mechanism must always be closed gradually. You need to obtain a good bed of red embers and the logs must be completely lit up before you close the air control completely. This can easily take up to one hour.

        Solution #3: The chimney may be too short. In order to obtain a sufficient draft, your chimney must have a minimum height. Twelve feet (from the heater to the chimney cap outside the house) is a minimum. A height of 15 feet or higher is ideal.

        Solution #4: Your exhaust system may be too tortuous or may lack a sufficiently steep slope. Ideally, your exhaust system should not have more than one 90° elbow. Furthermore, all horizontal sections should be as short as possible and have a minimum slope of 1/4" per foot.

        Solution #5: Your exhaust system may be oversized. When your chimney is oversized, the volume of air that needs to be warmed up is larger. It is therefore difficult to reach temperatures that will allow for a sufficient draft. Most advanced combustion systems (those certified to EPA/CSAB415.1-10) have a 6" flue outlet (152 mm). If your exhaust system does not have a 6" diameter, a solution is to insert a stainless liner with a 6" diameter inside the exhaust system.

        Whys is the BTU according to EPA test data smaller than the one advertised?

        You will notice a difference between the BTU output as per the EPA’s test data and what is advertised on our website and/or product literature. The maximum BTU output we advertise is what will be obtained with a full load of seasoned cordwood inserted inside the firebox. The EPA output, on the other hand, is what has been obtained during emissions testing. The EPA test procedure requires that a special type of wood be used and positioned inside the firebox in a manner that does not represent the way the firebox volume would normally be utilized using seasoned cordwood. The EPA test load is typically much smaller. Hence, the BTU as per the EPA’s test data is reduced. The BTU output that should be considered by a normal user is the one we advertise for seasoned cordwood.

        What R factor is required for my floor protection and how do I calculate it?
        What burn time will I get from my wood heater?

        The combustion time for an EPA or CSAB415.1-10 certified non-catalytic wood appliance depends on many factors, the most important being the size of its firebox. Heaters with a 2.0 cubic foot firebox or more will normally have longer burn times. From 6 to 8 hours is about the burn time you will get. Some companies will advertise longer burn times, but be careful, this calculation is made from the time you light the fire to the time there is absolutely no combustible left into the firebox. No matter what the appliance model is, the maximum BTU output will be obtained over approximately 33% of the total burn cycle. This represents 2 to 3 hours for a medium-size stove. So realistically, you will have to reload the unit every 3 or 4 hours in order to get the maximum heat out of your appliance when you are home. If you don’t reload the heater and let it burn the remaining fuel, your output will slowly decrease until there is no useful heat left to produce (we call this the “tail end” of the combustion cycle). This “tail end” will provide heat for another 4 to 5 hours. So if you are looking for a 6 to 8-hour burn time, make sure you choose an EPA or CSAB415.1-10 certified wood heater with a BTU output (using cordwood) of 60,000 BTU or more. Appliances with that kind of output all have fairly large fireboxes. If you are going to rely mostly on wood for heating and your house has more than 2,000 square feet, do not hesitate to choose one of our larger units (>85,000 BTU). Those appliances will have a burn time of approximately 8 to 10 hours.

        Can I install an EPA or CSAB415.1-10 certified heater on an 8-inch chimney?

        EPA or CSAB415.1-10 certified heaters function best on a 6-inch chimney (interior diameter). The problem with an 8-inch chimney is that the appliance may struggle to heat up the air volume contained inside the chimney. A hot chimney is required to create enough draft. Poor draft will inevitably lead to poor combustion, which will cause smoke rollbacks, dirty glass, lack of heat, and a large quantity of unburned fuel inside the firebox. It is therefore highly recommended to install a 6-inch liner inside the 8-inch chimney. This liner may be rigid or flexible.

        What makes a heater mobile-home approved?

        Mobile-home-approved stoves have gone through specific testing to show that they can source their combustion air entirely from outside the house. This is required because mobile homes (or manufactured homes) are often very airtight. Should there be a lack of combustion air, harmful levels of CO (carbon monoxide) could accumulate in the house. This is why mobile-home-approved stoves have an adapter that hooks up to the unit and connects to a fresh air intake on the outside wall of the house through an insulated pipe. 

        Do I need to install a fresh air intake on my wood heater??

        A fresh air intake is not mandatory for your wood heater, unless the unit is installed in a mobile home or if the local building code or the manufacturer requires it. If the heater is installed in an open room, in a house that is more or less air-tight, combustion air will normally be easily replaced. In this case, the installation of a fresh air intake is not required. It must, however, be noted that a fresh air intake, even if it is not mandatory, will always provide the advantage of better balancing the house with regards to combustion air. If the house has a powerful mechanical exhaust system that may be used while the heater is burning (ex: range hood), a fresh-air intake will be required.


        Downloads:

        View full details
        • Researched and ordered my fireplace from US FIreplace Store. Pricing was a fair value however, the customer service was EXCELLENT! I had an issue with the direct vent venting. I called US Fireplace and the correct items were sent out the next day AND Janessa stayed on top of my return authorization and sent me the permissions and documents I needed to return the incorrect item and no cost to me, including return shipping. Overall, I am a very satisfied customer and my fireplace looks and operates flawlessly. I am glad that I selected US FIreplace to source my direct vent fireplace. Thank you for the great service.

          Clay

          Monteagle, TN

        • I had placed an order, through Lowe's Home Improvement, for an Electric Firebox: Revillusion RBF42. Ordered 1st part of January. Was told I would have it in 3 weeks. When checking to see is it came in, was told it was delayed to 3/15. Was then told is was delayed until 4/25. Waited until 4/27 to check on it. Was then told it was now delayed until August. This firebox was going in a new Sun Room addition. I could not get my final inspection until the Firebox was installed. I went on line and googled for this same product. US Fireplace Store web site was given to me. This was on a Saturday. I call and reached a very nice man. Explain what I was look for. He checked and told me they had 30 of them in stock. I almost fell out of my chair. I clarified with him the product I was wanting. I ask how soon could I get it. He told me it would ship today. Again, was amazed. It arrived on the following Monday. What a pleasure and a relief working with US Fireplace Store and their employees. Exceed my expectations.

          Thomas W.

          Fort Mill, SC

        • Great prices, quick delivery and fast hassle free services on the issue I encountered. I had purchased an electric fireplace unit that would not fit into the existing fireplace space. With one email I was able to get the wrong fireplace refunded and picked up at my home at no extra cost and the new one I purchased and delivered free of charge. Great company.

          John P.

          Denvers, MA

        1 of 12
        • Live Chat Support

          No chatbots. Speak with a human. Average response time is 48 seconds.

        • Easy Returns

          Need to return the merchandise? We accept returns for 30 days from the date of delivery.

        • 7 Days/Week Service

          We're here to help on live chat, email & phone. 8:00 AM - 11:59 PM Eastern Time.

        • 20,000+ Products

          Best selection of hearth & heating products on the internet. Fireplaces, stoves, fire pits, heaters, log sets and more.

        • Pay Over Time

          0% APR is available for 3 and 12- month financing.* See if you prequalify today.

        • Staff Picks

          Check out the Staff Picks collection. See the top products selected by our team.